cFP-CTR-502 Technical Specifications:

ManufacturerNational Instruments
ModelcFP-CTR-502
Part Number777318-502
TypeCounter Module for Compact FieldPoint
Repair Evaluation$150

cFP-CTR-502

Home cFP-CTR-502

Part Number cFP-CTR-502
Manufacturer/Brand National Instruments
Description cFP-CTR-502, 8-Channel, Sourcing Counter Module for Compact FieldPoint
In Stock - Ships Today In Stock | Ships 3-5 Days

Speak to a sales representative for pricing & lead time:

Phone:
1-919-809-5227

• Quick Quotes:   Receive Price & Availability Today!
• Warranty:   1 Year Warranty Covered by Apex Waves
• Calibration:   Ask About Our Tiered Calibration Levels
• Option & Modules:   Confirm Your Requirements or Versions
• Repair:   Cost & Lead Time Available Upon Request for Service

National Instruments cFP-CTR-502 Counter Module for Compact Fieldpoint

The cFP-CTR-502 (Part number: 777318-502) Counter Module is separated from whatever is left of the FieldPoint bank. In the OFF express, this transistor is killed, permitting just a little spillage current to stream. The user should guarantee that the heap present at every channel will not draw over 1 A.

In FieldPoint programming, the user can design each count input channel to work with traits and summons. The accompanying segments portray the distinctive qualities and charges the user can choose when designing the count input channels.

To set the terminal check, enter an incentive from 0 to 65,535 in the Value field. The default esteem is 65,535. When the tally input channel surpasses its terminal tally, the count goes to 0 and triggers any outputs related with it. If the tally input channel utilizes one of the outside entryway inputs, checking is empowered when the door input signal is high and is debilitated when the flag is low. The outer gadget decides the high and low interims of the entryway input flag. If the user does not relate a door input channel with the tally input channel, then they can select Always Disabled or Always Enabled. The user can select Always Enabled if they need the tally input channel to tally constantly, regardless of whether there is nothing wired to the entryway input. Continuously Enabled is the default esteem.

ModelcFP-CTR-502
ManufacturerNational Instruments
Part Number777318-502
TypeCounter Module for Compact FieldPoint
Counter Inputs8
Resolution16 bits
Input Range5 to 30 VDC
Dimensions4.2 x 4.3 x 3.6 in.
Weight3.5 oz.
Warranty2-3 Year Warranty
cFP-CTR-502 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments cFP-CTR-502 Frequently Asked Questions

 

Question: Does the NI cFP-CTR-502 work with sinking devices?

 

Answer: The NI cFP-CTR-502 works with 5 to 30 VDC sinking devices and provides sinking outputs. A sinking device connects and disconnects a common terminal to and from the counter module.

 

Question: Do all the channels on the cFP-CTR-502 have LEDs?

 

Answer: All the channels on the cFP-CTR-502 module feature LEDs.

 

Question: How do you configure multiple counters to operate as one large counter with the cFP-CTR-502?

 

Answer: To configure the cFP-CTR-502 to have multiple counters operate as one large counter, you need to wire your signal into the input of counter 0, then set the following: Count Source: External Count Input, Terminal Count: 65535, Gate Source: Always Enabled, Read Reset Mode: Don't Reset on Read Noise Rejection: 50 kHz. Next, set counter 1 attributes to the following: Count Source: Previous Channel Terminal Count: 65535, gate Source: Always Enabled, Read Reset Mode: Don't Reset on Read Noise Rejection: 50 kHz. Then, you will create a Control @Multi channel by checking both channel 0 and channel 1 and then clicking on Create Item in the Channel Commands section.

 

Question: What could I use to measure speed with the NI cFP-CTR-502?

 

Answer: Using Fieldpoint with CVI would be the easiest way to measure speed with the NI cFP-CTR-502.

cFP-CTR-502

Main Image
cFP-CTR-502 National Instruments Counter Module for Compact FieldPoint | Apex Waves | Image

Secondary Image
cFP-CTR-502 National Instruments Counter Module for Compact FieldPoint | Apex Waves | Image

cFP-CTR-502, 8-Channel, Sourcing Counter Module for Compact FieldPoint

In Stock
Ships 3-5 Days

Call now for best pricing
919 809 5227
Rate the cFP-CTR-502

Rated 0/5 based on 0 ratings.
Manufacturer:National Instruments
Model:cFP-CTR-502
Part Number:777318-502
Type:Counter Module for Compact FieldPoint
Repair Evaluation:$150