PCI-CAN-LS Technical Specifications:

ManufacturerNational Instruments
ModelPCI-CAN/LS
Part Number778007-01
TypeCAN Interface Device
Repair Evaluation$150

PCI-CAN-LS

Home PCI-CAN-LS

Part Number PCI-CAN-LS
Manufacturer/Brand National Instruments
Description PCI-CAN/LS, 1-Port, CAN Interface Device

Speak to a sales representative for pricing & lead time:

Phone:
1-919-809-5227

• Quick Quotes:   Receive Price & Availability Today!
• Warranty:   1 Year Warranty Covered by Apex Waves
• Calibration:   Ask About Our Tiered Calibration Levels
• Option & Modules:   Confirm Your Requirements or Versions
• Repair:   Cost & Lead Time Available Upon Request for Service

National Instruments PCI-CAN/LS CAN interface Device

The PCI-CAN/LS is a low-speed CAN Interface Device by National Instruments. The part number of the device is 778007-01. The CAN Interface Device is a fault-tolerant CAN device used to program CAN applications. This model is designed to communicate with CAN devices with a low speed. The PCI-CAN/LS offers advanced functions like listen-only and self-reception filter modes. The PCI-CAN/LS interface device is equipped with special transceivers. This feature supports sleep/wake-up mode. This device is also compatible with the RTSI bus. The PCI-CAN/LS can be synchronized with DAQ, CAN, and motion devices for PCI. The RTSI bus also enables the PCI-CAN/LS to share signals.

The PCI-CAN/LS CAN Interface Device is a single port device. To interface with other devices, the PCI-CAN/LS is equipped with a 9-pin D-SUB connector. The DB-9 connector used in the PCI-CAN/LS is a male connector. A Philips SJA1000 CAN controller is also available in the device. This connector is used to implement CAN protocols. The PCI-CAN/LS is also compatible with 11-bit and 29-bit arbitration IDs. An Intel microprocessor is used in the PCI-CAN/LS device for timed CAN frame transfer. This model can sample data at a maximum rate of 125 kb/sec and supports 100% busload. The PCI-CAN/LS also incorporates a TJA1054A transceiver.  

The PCI-CAN/LS supports two operating systems. These systems are Windows and LabVIEW Real-Time. The supported versions of Windows are Windows 2000, NT, XP, Me, and 98. The PCI-CAN/LS CAN Interface dDevice comes with built-in Application and Driver software. The supported application software is the bus monitor utility. The built-in driver software is NI-CAN. The device with built-in NI-CAN is used in several industrial and research applications. NI-CAN is specifically ideal for automation applications.  

ModelPCI-CAN/LS
ManufacturerNational Instruments
Part Number778007-01
TypeCAN Interface Device
MicroprocessorIntel 80386EX
Ports1
TransceiverTJA1054A
Interface typeISO 11898
Maximum Baud Rate125 Kb/sec
I/O Connector9-pin male D-SUB
CAN_H, CAN_L Bus Lines–10 to +27 VDC
IsolationOptical Isolation up to 500 V
Power Requirements+ 5 VDC -- 800 mA
Dimensions8.15 in.by 6.9 in.
Software DriverNI-CAN
Warranty2-3 Year Warranty
PCI-CAN/LS ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-CAN/LS Frequently Asked Questions

 

Question: What is the supported NI PCI-CAN/LS driver software?

 

Answer: The supported NI PCI-CAN/LS driver software is NI-CAN.

 

Question: What does the LS in PCI-CAN/LS indicate?

 

Answer: LS indicates the PCI-CAN/LS is a low-speed CAN device.

 

Question: Does the NI PCI-CAN/LS meet the requirements for all automotive networks?

 

Answer: Yes, all National Instruments CAN interfaces meet physical requirements, as well as electrical requirements for automotive networks based on CAN.

 

Question: I’m getting an error message on the PCI-CAN/LS. What should I do if this continues?

 

Answer: Make sure you have the latest NI-CAN driver installed on the PCI-CAN/LS.

 

Question: Can I use a NI PCI-CAN/LS card with a high-speed device?

 

Answer: The NI PCI-CAN/LS, is a low-speed card, but it can be used on high speed devices. Check that the cables and the high-speed device itself are not internally terminated. You can do this by measuring the resistance between CAN_H and CAN_L with the cable connected and without the cable connected and comparing.

PCI-CAN-LS

Main Image
PCI-CAN/LS National Instruments CAN Interface Device | Apex Waves | Image

Secondary Image
PCI-CAN/LS National Instruments CAN Interface Device | Apex Waves | Image

PCI-CAN/LS, 1-Port, CAN Interface Device

Call

Call now for best pricing
919 809 5227
Rate the PCI-CAN-LS

Rated 0/5 based on 0 ratings.
Manufacturer:National Instruments
Model:PCI-CAN/LS
Part Number:778007-01
Type:CAN Interface Device
Repair Evaluation:$150