PXIe-5667 Technical Specifications:

ManufacturerNational Instruments
ModelPXIe-5667
Part Numbers782366-01, 782366-02, 782366-03, 782367-01, 782367-02
TypePXI Vector Signal Analyzer
Repair Evaluation$150

PXIe-5667

Home PXIe-5667

Part Number PXIe-5667
Manufacturer/Brand National Instruments
Description PXIe-5667, 7 GHz maximum, PXI Vector Signal Analyzer

Speak to a sales representative for pricing & lead time:

Phone:
1-919-809-5227

• Quick Quotes:   Receive Price & Availability Today!
• Warranty:   1 Year Warranty Covered by Apex Waves
• Calibration:   Ask About Our Tiered Calibration Levels
• Option & Modules:   Confirm Your Requirements or Versions
• Repair:   Cost & Lead Time Available Upon Request for Service

National Instruments PXIe-5667 PXI Vector Signal Analyzer

The PXIe-5667 (Part Numbers: 782366-01, 782366-02, 782366-03, 782367-01, 782367-02) is an advanced Vector Signal Analyzer from National Instruments. The instrument comes with the onboard memory to enable various RF measurements. The size of the memory is 64 MB or 256 MB. There is one input channel. The Analyzer provides a frequency range from 20 Hz to 3.6 GHz or 7 GHz. The instrument offers optimized solutions for various testing requirements, such as spectrum monitoring. The PXIe-5667 can be used for the following applications: interference detection, spectrum regulation, and radio monitoring, as well as many applications that involve ITU standards.

The NI PXIe-5667 allows the user to implement sub-octave pre-selection of the bandwidth. The instrument also has a low value for noise figure which is less than 12 dB. The instrument comes with seven built-in IF filters to further enhance the measurement capabilities of the device. Their bandwidth value ranges from 30 kHz to 50 MHz. The hardware modules of the PXIe-5667 Analyzer are interconnected through coaxial cables. Their connectors are the SMA type.

The PXIe-5667 Vector Signal Analyzer strictly follows the industry standards, enabling the user to integrate it with ease for measurement applications. The value for the average noise level of the instrument is -161 dBm per hertz for the frequency range from 87 MHz to 1.5 GHz. The instrument offers an instantaneous bandwidth value of 25 MHz. The device also has the capability to offer the third order intercept of +21 dBm.  

ModelPXIe-5667
Part Numbers782366-01, 782366-02, 782366-03, 782367-01, 782367-02
ManufacturerNational Instruments
TypePXI Vector Signal Analyzer
Third-Order Intercept+21 dBm
Onboard Memory Size64 MB or 256 MB
Bandwidth25 MHz or 50 MHz
Front Panel ConnectorSMA female
Channels1
Warranty2-3 Year Warranty
PXIe-5667 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PXIe-5667 Frequently Asked Questions

 

Question: What are the differences between the part numbers for the PXIe-5667?

 

Answer: The PXIe-5667 has a few variations in the specifications. For example, part number 782366-01 has 25 MHz bandwidth, -161 dBm/Hz between 87 MHz and 1.5 GHz average noise level, 64 MB onboard memory, 20 Hz to 3.6 GHz, and does not have a preamplifier. All other part numbers for the PXIe-5667 have a preamplifier included. Next, part number 782366-02 has the same specifications as the former part number but with 256 MB onboard memory. Part number 782366-03 has 50 MHz bandwidth, -161 dBm/Hz between 87 MHz and 1.5 GHz average noise level, 256 MB onboard memory, and 20 Hz to 3.6 GHz frequency range. Part number 782367-01 has 25 MHz bandwidth, -161 dBm/Hz between 87 MHz and 1.5 GHz average noise level, 256 MB onboard memory, and 20 Hz to 7 GHz frequency range. Lastly, part number 782367-02 has the same specifications as the previous part number but has 50 MHz bandwidth.

 

Question: Which parts comprise the PXIe-5667 Vector Signal Analyzer?

 

Answer: These parts comprise the PXIe-5667 Vector Signal Analyzer: the PXIe-5603 RF Signal Downconverter, PXIe-5622 IF Digitizer, PXIe-5653 RF Analog Signal Generator, PXIe-5693 RF Preselector Module, and the PXIe-5694 IF Conditioning Module. There is not a physical device called PXIe-5667.

 

Question: How much does the NI PXIe-5667 weigh?

 

Answer: The NI PXIe-5667 is comprised of several modules: the PXIe-5693 weighs 16.4 oz, the PXIe-5653 weighs 37.8 oz, the PXIe-5603 weighs 32.0 oz, the PXIe-5694 weighs 16.4 oz, and the PXIe-5622 weighs 13.3 oz.

 

Question: Which items are needed to operate the PXIe-5667?

 

Answer: To operate the PXIe-5667, a PXI Express Chassis such as the PXIe-1075 is needed, along with a PXI Express Embedded Controller or MXI Controller system that meets the requirements in the manual.

PXIe-5667

Main Image
PXIe-5667 National Instruments PXI Vector Signal Analyzer | Apex Waves | Image

Secondary Image
PXIe-5667 National Instruments PXI Vector Signal Analyzer | Apex Waves | Image

PXIe-5667, 7 GHz maximum, PXI Vector Signal Analyzer

Call

Call now for best pricing
919 809 5227
Rate the PXIe-5667

Rated 0/5 based on 0 ratings.
Manufacturer:National Instruments
Model:PXIe-5667
Part Numbers:782366-01, 782366-02, 782366-03, 782367-01, 782367-02
Type:PXI Vector Signal Analyzer
Repair Evaluation:$150