PCI-6115 Technical Specifications:

ManufacturerNational Instruments
ModelPCI-6115
Part Numbers778534-01 and 778554-01
SeriesS Series
TypeMultifunction I/O Device
Repair Evaluation$150

PCI-6115

Home PCI-6115

Part Number PCI-6115
Manufacturer/Brand National Instruments
Description PCI-6115, 4 AI, 2 AO, 8 DIO, Multifunction I/O Device

Speak to a sales representative for pricing & lead time:

Phone:
1-919-809-5227

• Quick Quotes:   Receive Price & Availability Today!
• Warranty:   1 Year Warranty Covered by Apex Waves
• Calibration:   Ask About Our Tiered Calibration Levels
• Option & Modules:   Confirm Your Requirements or Versions
• Repair:   Cost & Lead Time Available Upon Request for Service

National Instruments PCI-6115 Multifunction I/O Device

The PCI-6115 is a Multifunction I/O Device from the S Series by NI (Part numbers: 778534-01, 778554-01, 184529D-03). This device has two analog input FIFO buffer sizes available with different part numbers. Part number 778534-01 has 16 MS FIFO buffer size and part number 778554-01 has 32 MS FIFO buffer size.  This device offers four analog input channels. These analog input channels are pseudo differential, with a 12 bit resolution. This model allows the user to input data for various measurement requirements. The instrument also has a simultaneous sampling capability, which is accompanied by a maximum sampling rate of 10 MS per second for each channel–the minimum rate is 20 kS per second. There are also two analog output channels with a maximum update rate of 4 MS per second, and a 12 bit resolution. Additionally, it has 8 TTL/CMOS digital I/O channels. The PCI-6115 Multifunction I/O Device can be used in the following applications: IF digitization, radar, sonar, ultrasound, high-energy physics, 42 V automotive applications, and transient/ballistics measurements.

The NI PCI 6115 incorporates two counters. The counters both have 24 bit resolution. This feature makes the device suitable for various applications that involve stimulus or response calculations. These measurements require a high level of accuracy and synchronization capabilities. The value of absolute accuracy is 184 mV for the analog input channels. The device is powered through a BUS power interface. The PCI-6115 additionally incorporates eight digital channels. These channels are bidirectional. The dedicated A/D converters for each channel allow the user to reach quicker sampling rates for each channel, simultaneous sampling, and improved dynamic preciseness for transient or frequency measurements. The device has a recommended warm-up time of 15 minutes and should be calibrated at least once every year.

The NI DAQ PCI-6115 can be used with the NI-DAQmx driver, which simplifies the configuration and measurement procedure for the users. The instrument additionally has various event trigger applications available–this further enhances its operational capabilities. The device hardware can be programmed using software packages/application development environments (ADEs) like LabVIEW, LabWindows/CVI, or Measurement Studio. The NI device measures 12.3 x 4.2 in. in physical dimensions.

Apex Waves will continue to Buy, Sell, and Repair EOL NI Hardware in perpetuity. While the PCI-6115 entered the NI Maintenance phase on March 31, 2022, it will remain available with Apex Waves. Request your quote today!

ModelPCI-6115
ManufacturerNational Instruments
Part Numbers778534-01, 778554-01, 184529D-03
SeriesS Series
TypeMultifunction I/O Device
Analog Input Channels4
Analog Output Channels2
Dimensions12.3 in. x 4.2 in.
Calibration Interval1 year
WarrantyThree Year Warranty
PCI-6115 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-6115 Frequently Asked Questions

 

Question: What is the difference between the two versions of the PCI 6115?

 

Answer: Part number 778534-01 for the PCI 6115 has 16 MS analog input FIFO buffer size, while part number 778554-01 has 32 MS analog input FIFO buffer size.

 

Question: What is the slew rate of the NI PCI 6115?

 

Answer: The NI PCI 6115 has a slew rate of 130 V/ms.

 

Question: What is the digital I/O compatibility for the NI DAQ PCI 6115?

 

Answer: The digital I/O compatibility for the NI DAQ PCI 6115 is TTL/CMOS.

 

Question: What is the NI PCI-6115 driver?

 

Answer: The NI PCI-6115 driver is NI-DAQmx.

PCI-6115

Main Image
PCI-6115 National Instruments Multifunction I/O Device | Apex Waves | Image

Secondary Image
PCI-6115 National Instruments Multifunction I/O Device | Apex Waves | Image

PCI-6115, 4 AI, 2 AO, 8 DIO, Multifunction I/O Device

Call

Call now for best pricing
919 809 5227
Rate the PCI-6115

Rated 0/5 based on 0 ratings.
Manufacturer:National Instruments
Model:PCI-6115
Part Numbers:778534-01 and 778554-01
Series:S Series
Type:Multifunction I/O Device
Repair Evaluation:$150