Fast Quote
SCXI-1125 National Instruments Voltage Input Module | Apex Waves | ImageSCXI-1125 National Instruments Voltage Input Module | Apex Waves | Image
SCXI-1125 National Instruments Voltage Input Module | Apex Waves | Image
SCXI-1125 National Instruments Voltage Input Module | Apex Waves | Image

Request a quote and receive a price in about 15 minutes.

Authorize.net Visa American Express

Quick Quotes

Fast Shipping

1 Year Warranty

Rate the SCXI-1125
Rated 4.7/5 based on 10 ratings.
 

SCXI-1125 Technical Specifications:

ManufacturerNational Instruments
ModelSCXI-1125
Part Number776572-25
TypeVoltage Input Module
Repair Evaluation$150

SCXI-1125

Home SCXI-1125

Part Number SCXI-1125
Manufacturer/Brand National Instruments
Description SCXI-1125, 8-Channel, Voltage Input Module

Speak to a sales representative for pricing & lead time:

Phone:
1-919-809-5227

• Quick Quotes:   Receive Price & Availability Today!
• Warranty:   1 Year Warranty Covered by Apex Waves
• Calibration:   Ask About Our Tiered Calibration Levels
• Option & Modules:   Confirm Your Requirements or Versions
• Repair:   Cost & Lead Time Available Upon Request for Service

National Instruments SCXI-1125 Voltage Input Module

The NI SCXI-1125 Voltage Input Module (Part Number: 776872-25) offers 300 Vrms of working isolation and low pass filtering for every analog input channel–all 8 of them. Its architecture is perfect for intensification and confinement of millivolt sources, volt sources, 0 to 20 mA, 4 to 20 mA, and thermocouples. The SCXI-1125 can multiplex its eight channels into a single channel of the DAQ gadget, while also allowing the user to add modules to expand channel count. This module additionally offers parallel-mode operation for expanded output capability.

The NI SCXI-1125 contains calibration hardware to invalid out mistake sources. With programmable offset calibration, software-programmable analog switches ground the inputs of every one of the instrumentation enhancers for offset error calibration. A locally available EEPROM stores the calibration constants for each channel for each input extend in a client characterized zone. The EEPROM also stores an arrangement of factory calibration constants in permanent memory, which cannot be altered. The NI-DAQ driver software straightforwardly utilizes the calibration constants to verify for gain and offset errors. The device has an output range of ±5.0 V, and weighs 22.6 oz. It has the dimensions: 7.4 x 6.8 x 1.2 in.

In this model, each channel incorporates an automatic low pass filter that the user can configure for 4 Hz or 10 kHz. With the SCXI-1125, the user can perform irregular scanning, meaning they can choose just the channels from which they need to pick information, then scan channels in any order. Each channel is independently confined with a working common-mode voltage of 300 Vrms between channels or channel to earth. Furthermore, the SCXI-1125 is CE guaranteed as double insulated, Category II of operational isolation.

The NI-DAQmx 9.0 (or later versions) driver software is required to configure and program the SCXI-1125. Also, the device is compatible with any one of the following application development environments (ADEs): LabVIEW, LabWindows/CVI, Measurement Studio. The device software can be configured using the Measurement & Automation Explorer tool.

SCXI-1125 End of Life Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves.

The SCXI-1125 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the SCXI-1125 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the SCXI-1125 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the SCXI-1125!

ModelSCXI-1125 (776572-25)
ManufacturerNational Instruments
SeriesSCXI Series
TypeVoltage Input Module
Channels8
Output Range±5.0 V
Dimensions7.4 x 6.8 x 1.2 in.
Weight22.6 oz.
WarrantyThree Year Warranty
SCXI-1125 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments SCXI-1125 Frequently Asked Questions

 

Question: What is the suggested warm-up time for the NI SCXI-1125?

 

Answer: The suggested warm-up time for the NI SCXI-1125 is 15 minutes.

 

Question: What are the bandwidth filter options for the SCXI-1125?

 

Answer: For the SCXI-1125, the bandwidth filter options are 4 Hz and 10 kHz.

 

Question: Does the SCXI-1125 have a self-calibration capability?

 

Answer: The SCXI-1125 does support self-calibration. The SCXI calibration VI should be used for this.

 

Question: What type of A/D Converter structure does the NI SCXI-1125 have?

 

Answer: The NI SCXI-1125 is a signal conditioning module, so it must be interfaced to a compatible DAQ card for A/D conversion.

 

Question: Which types of output modes does the SCXI-1125 support?

 

Answer: The SCXI-1125 supports parallel and multiplexed output modes.

SCXI-1125

Main Image
SCXI-1125 National Instruments Voltage Input Module | Apex Waves | Image

Secondary Image
SCXI-1125 National Instruments Voltage Input Module | Apex Waves | Image

SCXI-1125, 8-Channel, Voltage Input Module

Call

Call now for best pricing
919 809 5227
Rate the SCXI-1125

Rated 0/5 based on 0 ratings.
Manufacturer:National Instruments
Model:SCXI-1125
Part Number:776572-25
Type:Voltage Input Module
Repair Evaluation:$150