Fast Quote
SCXI-1308 National Instruments Terminal Block | Apex Waves | ImageSCXI-1308 National Instruments Terminal Block | Apex Waves | Image
SCXI-1308 National Instruments Terminal Block | Apex Waves | Image
SCXI-1308 National Instruments Terminal Block | Apex Waves | Image

Request a quote and receive a price in about 15 minutes.

Authorize.net Visa American Express

Quick Quotes

Fast Shipping

1 Year Warranty

Rate the SCXI-1308
Rated 4.7/5 based on 16 ratings.
 

SCXI-1308 Technical Specifications:

ManufacturerNational Instruments
ModelSCXI-1308
Part Number777687-08
SeriesSCXI Series
TypeCurrent Input Terminal Block
Repair Evaluation$150

SCXI-1308

Home SCXI-1308

Part Number SCXI-1308
Manufacturer/Brand National Instruments
Description SCXI-1308, 78 Screw Terminal, 1/4 W Wattage, Current Input Terminal Block

Speak to a sales representative for pricing & lead time:

Phone:
1-919-809-5227

• Quick Quotes:   Receive Price & Availability Today!
• Warranty:   1 Year Warranty Covered by Apex Waves
• Calibration:   Ask About Our Tiered Calibration Levels
• Option & Modules:   Confirm Your Requirements or Versions
• Repair:   Cost & Lead Time Available Upon Request for Service

National Instruments SCXI-1308 Current Input Terminal Block

The SCXI-1308 (Part Number: 777687-08) 32-Channel Terminal Block is shielded with 78 screw terminals that can be joined to the following modules: the SCXI-1102/B/C and the SCXI-1100 modules. There are 32 precision resistors of 249 Ω that can change current to voltage when measuring 0 to 20 mA and 4 to 20 mA process current sources. The SCXI module being used with the SCXI-1308 then measures the voltage, allowing the data acquisition board obtains the voltage. Thirty-two pairs of screw terminals can be joined to the 32 differential inputs of the SCXI modules. A single pair of terminals can be linked to the module’s chassis ground pins. Three terminals link to the SCXI module OUTPUT and AOREF pins, along with the SCXIbus guard. The remaining terminals are saved for operation in the future.

To arrange and operate the NI SCXI 1308 Terminal Block, there are several required items: the Installation Guide, an SCXI chassis, the SCXI-1102/B/C or SCXI-1100 module, No. 1 and No. 2 Philips-head screwdrivers, and 1/10 inch and ¼ inch flathead screwdrivers. The installation process involves linking the Terminal Block to the SCXI module’s front connector, then tightening the bottom and top thumbscrews on the rear of the SCXI-1308 to make sure it is secure.

The SCXI 1308 Current Input Terminal Block can convert current to voltage, then measure the voltage and the data acquisition board obtains the voltage. The voltage measured for a 4 to 20 mA current source will fall between 0.996 to 4.98 VDC. The NI SCXI-1308 has the capability to measure current and voltage sources. While measuring voltage signals, the user should remove the current-loop resistor for that specific input channel. It has channel-to-channel and channel-to-earth voltages of up to 30 Vrms and 42.4 Vpeak or 60 VDCs. The NI device has an operating temperature range of 0° to 50° C, a storage temperature range of –20° to 70° C, and a non-condensing relative humidity range of 5% to 90%.

SCXI-1308 Obsolete Status has been announced by National Instruments, but the Terminal Block will still be available for purchase and repairs by Apex Waves. 

The SCXI-1308 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the SCXI-1308 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the SCXI-1308 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the SCXI-1308!

ModelSCXI-1308
Part Number777687-08
ManufacturerNational Instruments
TypeCurrent Input Terminal Block
Channels32
Screw Terminals78
Precision ResistorsThirty-two 249 Ω
Current Input Reading Ranges0 to 20 mA and 4 to 20 mA
WarrantyThree Year Warranty
SCXI-1308 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments SCXI-1308 Frequently Asked Questions

 

Question: What is the maximum voltage of the SCXI-1308?

 

Answer: The maximum voltage of the SCXI-1308 is 30 Vrms and 42.4 Vpeak or 60 VDC channel-to-channel and channel-to-earth and 10 VDC or 10 Vrms Intra-channel (+) or (-).

 

Question: What is the current input of the NI SCXI-1308?

 

Answer: The current input of the NI SCXI-1308 is 0 to 20 mA.

 

Question: What does Error -89120 regarding the NI SCXI 1308 mean?

 

Answer: Error -89120 occurs when the code in a subVI of the LabVIEW NI-CAN shipping example references timing terminals for an SCXI module. However, the NI SCXI 1308 does not have timing terminals.

SCXI-1308

Main Image
SCXI-1308 National Instruments Terminal Block | Apex Waves | Image

Secondary Image
SCXI-1308 National Instruments Terminal Block | Apex Waves | Image

SCXI-1308, 78 Screw Terminal, 1/4 W Wattage, Current Input Terminal Block

Call

Call now for best pricing
919 809 5227
Rate the SCXI-1308

Rated 0/5 based on 0 ratings.
Manufacturer:National Instruments
Model:SCXI-1308
Part Number:777687-08
Series:SCXI Series
Type:Current Input Terminal Block
Repair Evaluation:$150