SCXI-1321 Technical Specifications:

ManufacturerNational Instruments
ModelSCXI-1321
Part Number777687-21
SeriesSCXI Series
TypeOffset-Null and Shunt Calibration Terminal Block
Repair Evaluation$150

SCXI-1321

Home SCXI-1321

Part Number SCXI-1321
Manufacturer/Brand National Instruments
Description SCXI-1321, 18 Screw Terminals, Offset-Null and Shunt Calibration Terminal Block

Speak to a sales representative for pricing & lead time:

Phone:
1-919-809-5227

• Quick Quotes:   Receive Price & Availability Today!
• Warranty:   1 Year Warranty Covered by Apex Waves
• Calibration:   Ask About Our Tiered Calibration Levels
• Option & Modules:   Confirm Your Requirements or Versions
• Repair:   Cost & Lead Time Available Upon Request for Service

National Instruments SCXI-1321 Offset-Null and Shunt Calibration Terminal Block

The NI SCXI-1321 (Part Number: 777687-21) is ideal for applications with strain gauges, RTDs, or thermistors. This model is well-suited for temperature or voltage applications with a high quantity of channels. This High-Voltage Terminal Block is shielded to allow swift, reliable signal connections. The SCXI-1321 brings nulling and shunt calibration to SCXI-1121 strain gauge applications but can only be used with the SCXI-1121 module revision C or later. There are 18 screw terminals on the NI SCXI-1321.

There is also a front-panel trimming potentiometer, which enables the user to manually null out the offset voltage or bridge transducers. Every channel has shunt calibration circuits that can be controlled as a group via software. The user can also trigger a switch on the SCXI 1321 Terminal Block to link a 301 k Ohm shunt resistor in parallel with the strain gauge. The nulling and shunt resistor on the Terminal Block are socketed, so they can be customized by the user with ease. The device has a maximum field wire gauge of 26-16 AWG, a cold junction sensor output and accuracy of ±10 mV/ËšC and 1.3 °C respectively. It has a maximum working voltage of 300 V (CAT II).

Offset nulling is a hardware nulling process with Wheatstone-bridge transducers that have an initial offset error. Fixing this error will increase measurement preciseness. The nulling circuitry on the SCXI-1321 will work with quarter-bridge, half-bridge, and full-bridge strain-gauge arrangements. Every channel has separate nulling circuitry, as well as a designated trimming potentiometer. For example, Channel 0 corresponds to Potentiometer R1. Channel 1 corresponds to Potentiometer R2. Next, Channel 2 corresponds to Potentiometer R14. Finally, Channel 3 corresponds to Potentiometer R15.

It has a recommended operating temperature range of 0 to 50 °C, a storage temperature range of –20 to 70 °C, and a non-condensing relative humidity range of 10 to 90%. The NI device is designed to comply with the following electrical safety standards: IEC 61010-1, EN 61010-1, UL 3111-1, UL61010B-1, and CAN/CSA C22.2 No. 1010.1.

SCXI-1321 Obsolete Status has been announced by National Instruments, but the Terminal Block will still be available for purchase and repairs by Apex Waves.

The SCXI-1321 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the SCXI-1321 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the SCXI-1321 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the SCXI-1321!

ModelSCXI-1321
Part Number777687-21
ManufacturerNational Instruments
TypeOffset-Null and Shunt Calibration Terminal Block
For Use With:SCXI-1121
Sensor Output±10 mV/ËšC
Maximum Field Wire Gauge26-16 AWG
Acuracy1.3 °C
WarrantyThree Year Warranty
SCXI-1321 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments SCXI-1321 Frequently Asked Questions

 

Question: What module can the NI SCXI-1321 be used with?

 

Answer: The NI SCXI-1321 terminal block can only be used with the SCXI-1121 revision C or later modules.

 

Question: Does the SCXI 1321 have a socketed shunt resistor?

 

Answer: Yes, the SCXI 1321 has a socketed shunt resistor for strain-gauge shunt calibration.

 

Question: Does the National Instruments SCXI-1321 work with the Wheatstone bridge transducers?

 

Answer: The National Instruments SCXI-1321 was designed to work with the Wheatstone bridge transducers.

 

Question: Can the SCXI-1321 accommodate thermocouples?

 

Answer: The SCXI-1321 can easily accommodate thermocouples, RTDs, thermistors, millivolt sources, and current-loop receivers.

SCXI-1321

Main Image
SCXI-1321 National Instruments Terminal Block | Apex Waves | Image

Secondary Image
SCXI-1321 National Instruments Terminal Block | Apex Waves | Image

SCXI-1321, 18 Screw Terminals, Offset-Null and Shunt Calibration Terminal Block

Call

Call now for best pricing
919 809 5227
Rate the SCXI-1321

Rated 0/5 based on 0 ratings.
Manufacturer:National Instruments
Model:SCXI-1321
Part Number:777687-21
Series:SCXI Series
Type:Offset-Null and Shunt Calibration Terminal Block
Repair Evaluation:$150