SCXI-1324 Technical Specifications:

ManufacturerNational Instruments
ModelSCXI-1324
Part Number777687-24
SeriesSCXI Series
TypeHigh-Voltage Screw Terminal Block
Repair Evaluation$150

SCXI-1324

Home SCXI-1324

Part Number SCXI-1324
Manufacturer/Brand National Instruments
Description SCXI-1324, 48 Screw Terminals, 250 Vrms Channel to Channel, High-Voltage Screw Terminal Block

Speak to a sales representative for pricing & lead time:

Phone:
1-919-809-5227

• Quick Quotes:   Receive Price & Availability Today!
• Warranty:   1 Year Warranty Covered by Apex Waves
• Calibration:   Ask About Our Tiered Calibration Levels
• Option & Modules:   Confirm Your Requirements or Versions
• Repair:   Cost & Lead Time Available Upon Request for Service

National Instruments SCXI-1324 High-Voltage Screw Terminal Block

The NI SCXI-1324 (Part Number: 777687-24) is ideal for high-voltage general-purpose switching applications. This model is meant to be used with the SCXI-1160 Relay Module; it easily mounts to the front of the module. The SCXI-1324 is a Shielded Terminal Block, which enables swift, effortless signal connections. The 48 screw terminals on the SCXI-1324 High-Voltage Terminal Block link to the 16 relays on the interior of the SCXI-1160 Relay Module. This model does not have a cold-junction sensor, unlike some of the other SCXI Terminal Blocks. The common-mode isolation for the SCXI 1324 is 250 VRMS for both channel to channel and channel to ground. The device has a load or signal current of 2 A maximum per channel.

When the user is ready to connect the NI SCXI-1324 to the SCXI-1160, first they need several other items. AN SCXI chassis, wire cutter, wire insulation stripper, long-nose pliers, a 1/8 in. flathead screwdriver, and Number 1 and 2 Philips-head screwdrivers are required. Once these items are ready, the user can join the module front connector to the appropriate connector on the High-Voltage Screw Terminal Block. Then, the user can tighten the top and bottom thumbscrews on the rear of the SCXI-1324 to make sure it will stay in place.

If the user would like to clean the National Instruments SCXI 1324 Terminal Block, it is best to initially use a soft, nonmetallic brush to get the dust off the model. The user can get other contaminants off of the Terminal Block with deionized water and a firm nonmetallic brush. Before returning the SCXI-1324 to operation, it should be fully dry with all contaminants removed.  

The SCXI-1324 has a maximum field wire gauge of 26 to 16 AWG. The NI device has recommended operating and storage temperature ranges of 0 to 50 °C and –20 to 70 °C respectively, and a non-condensing relative humidity range of 5 to 90%. It is designed to comply with the following electrical safety standards: IEC 61010-1, UL 3111-1, and CAN/CSA C22.2 No. 1010.1. To get help on various issues, you can visit the technical support section at www.ni.com/support.

ModelSCXI-1324
Part Number777687-24
ManufacturerNational Instruments
TypeHigh-Voltage Screw Terminal Block
Screw Terminals48
For Use With:SCXI-1160 Relay Module
Load or Signal Current2A maximum per channel
Maximum Field Wire Gauge26-16 AWG
WarrantyThree Year Warranty
SCXI-1324 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments SCXI-1324 Frequently Asked Questions

 

Question: What should I do if the NI SCXI-1324 is damaged?

 

Answer: If the NI SCXI-1324 is damaged, turn the device off and have it checked by service-trained personnel right away.

 

Question: Can the SCXI 1324 be used with high common-mode voltages?

 

Answer: Yes, the SCXI 1324 can be used with high common-mode voltages. Just be sure to insulate your signal wires for the highest input voltage.

 

Question: What wire rating do I need to look for to use with the SCXI-1324?

 

Answer: The SCXI-1324 should only be used with 26-14 AWG wire with a rating of 300 V and 60 °C for signals that may come in contact with 250 V.

SCXI-1324

Main Image
SCXI-1324 National Instruments Terminal Block | Apex Waves | Image

Secondary Image
SCXI-1324 National Instruments Terminal Block | Apex Waves | Image

SCXI-1324, 48 Screw Terminals, 250 Vrms Channel to Channel, High-Voltage Screw Terminal Block

Call

Call now for best pricing
919 809 5227
Rate the SCXI-1324

Rated 0/5 based on 0 ratings.
Manufacturer:National Instruments
Model:SCXI-1324
Part Number:777687-24
Series:SCXI Series
Type:High-Voltage Screw Terminal Block
Repair Evaluation:$150