SCXI-1338 Technical Specifications:

ManufacturerNational Instruments
ModelSCXI-1338
Part Number777687-38
SeriesSCXI Series
TypeCurrent Input Terminal Block
Repair Evaluation$150

SCXI-1338

Home SCXI-1338

Part Number SCXI-1338
Manufacturer/Brand National Instruments
Description SCXI-1338, 18 Screw Terminals, Current Input Terminal Block

Speak to a sales representative for pricing & lead time:

Phone:
1-919-809-5227

• Quick Quotes:   Receive Price & Availability Today!
• Warranty:   1 Year Warranty Covered by Apex Waves
• Calibration:   Ask About Our Tiered Calibration Levels
• Option & Modules:   Confirm Your Requirements or Versions
• Repair:   Cost & Lead Time Available Upon Request for Service

National Instruments SCXI-1338 Current Input Terminal Block

The NI SCXI-1338 (Part Number: 777687-38) can be used with the SCXI-1120, SCXI-1120D, SCXI-1125, or SCXI-1126 module. This Terminal Block can be mounted to the front of the SCXI module and is shielded for swift, simple signal connections. The SCXI-1338 8-Channel Current Input Terminal Block is well-suited for high-precision current measurements. Every input has a 249 Ohm precision resistor, enabling the user to read 0 to 20 mA or 4 to 20 mA current inputs. There are 18 screw terminals on this Terminal Block, which allows for simple connection. Eight pairs of the screw terminals are utilized for signal connection to the eight module inputs, while the remaining pair of terminals links to the SCXI chassis ground. The device has a maximum working voltage of 300 Vrms or ±300 VDC.

The National Instruments SCXI-1338 Terminal Block can measure current and voltage sources. While measuring voltage signals, the user must get rid of the current-loop resistor for that specific input channel. The user can recognize the resistor for a certain channel by its reference designator, which matches the channel the resistor is across. As an example, input channel 0 has resistor R0 across the channel.

The NI SCXI-1338 Current Input Terminal Block can be calibrated. Since this model is not user-adjustable, calibrating the SCXI 1338 will solely confirm the performance. Calibration verifies that the Terminal Block is operating within the NI standards. This Terminal Block should be calibrated a minimum of once per year, but can be calibrated every 90 days or six months depending on the demands of the user’s application.

The following items are required to setup and use the SCXI-1338 terminal block:

·         A SCXI chassis

·         One of the following–SCXI-1120, SCXI-1120D, SCXI-1125, and SCXI-1126.

·         Number 1 and 2 Phillips-head screwdriver

·         A 1/8 in. flathead screwdriver

·        Long-nose pliers

·         A wire cutter

·        Wire insulation stripper

The NI device weighs 7 oz, and measures 7.000 x 3.125 x 1.200 in. in physical dimensions. It has a recommended operating temperature range of 0 to 50 °C, a storage temperature range of –20 to 70 °C, and a non-condensing relative humidity range of 10 to 90%.

SCXI-1338 Obsolete Status has been announced by National Instruments, but the Terminal Block will still be available for purchase and repairs by Apex Waves.

The SCXI-1338 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the SCXI-1338 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the SCXI-1338 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the SCXI-1338!

ModelSCXI-1338
ManufacturerNational Instruments
Part Number777687-38
TypeCurrent Input Terminal Block
Screw Terminals18
CouplingDC
Maximum Working Voltage300 Vrms or ±300 VDC
Dimensions7.0 by 3.125 by 1.2 in.
Weight7 oz.
WarrantyThree Year Warranty
SCXI-1338 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments SCXI-1338 Frequently Asked Questions

 

Question: What is the maximum wire gauge for the SCXI-1338?

 

Answer: 16 AWG is the maximum wire gauge for the SCXI-1338.

 

Question: How many current-receiver resistors does the NI SCXI-1338 have?

 

Answer: There are eight current-receiver resistors (one for each channel) for the NI SCXI-1338.

 

Question: Which items are necessary to operate the SCXI 1338?

 

Answer: To use the SCXI 1338, an SCXI chassis, either an SCXI-1120, SCXI-1120D, SCXI-1125, or SCXI-1126, Number 1 and 2 Philips-head screwdrivers, a 1/8 inch flathead screwdriver, long-nose pliers, a wire cutter, and a wire insulation stripper are necessary.

 

Question: What type of SCXI chassis should be used with the SCXI-1338?

 

Answer: The SCXI-1338 should be used with a UL-listed SCXI chassis.

SCXI-1338

Main Image
SCXI-1338 National Instruments Current Input Terminal Block | Apex Waves | Image

Secondary Image
SCXI-1338 National Instruments Current Input Terminal Block | Apex Waves | Image

SCXI-1338, 18 Screw Terminals, Current Input Terminal Block

Call

Call now for best pricing
919 809 5227
Rate the SCXI-1338

Rated 0/5 based on 0 ratings.
Manufacturer:National Instruments
Model:SCXI-1338
Part Number:777687-38
Series:SCXI Series
Type:Current Input Terminal Block
Repair Evaluation:$150