Fast Quote
Tektronix MDO3014 Mixed Domain Oscilloscope | Apex Waves | ImageTektronix MDO3014 Mixed Domain Oscilloscope | Apex Waves - Wiring Diagram Image
Tektronix MDO3014 Mixed Domain Oscilloscope | Apex Waves | Image
Tektronix MDO3014 Mixed Domain Oscilloscope | Apex Waves - Wiring Diagram Image

Request a quote and receive a price in about 15 minutes.

Authorize.net Visa American Express

Quick Quotes

Fast Shipping

1 Year Warranty

Rate the MDO3014
Rated 4.5/5 based on 11 ratings.
 

MDO3014 Technical Specifications:

ManufacturerTektronix
Model NumberMDO3014
Product TypeMixed Domain Oscilloscope

MDO3014

Home MDO3014

Part Number MDO3014
Manufacturer/Brand Tektronix Inc
Description Mixed Domain Oscilloscope

Speak to a sales representative for pricing & lead time:

Phone:
1-919-809-5227

• Quick Quotes:   Receive Price & Availability Today!
• Warranty:   1 Year Warranty Covered by Apex Waves
• Calibration:   Ask About Our Tiered Calibration Levels
• Option & Modules:   Confirm Your Requirements or Versions
• Repair:   Cost & Lead Time Available Upon Request for Service

Tektronix MDO3014 Mixed Domain Oscilloscope

The MDO3014 Mixed Domain Oscilloscope designed by Tektronix is a high performing 6-in-1 oscilloscope that includes: an arbitrary function generator, integrated spectrum analyzer, protocol analyzer, logic analyzer, and digital voltmeter/counter. This model is suitable for applications such as education, EMI troubleshooting, and design and debug. The MDO3014 can be customized and upgraded at any time, according to the user’s specifications.

One of the features of the MDO3014 is Wave Inspector, which allows the user to navigate waveforms and perform automated searches, and spot events of interest quickly. Another feature of this model are the integrated analysis tools such as waveform and screen- based cursors, advanced waveform math, FFT assessment, automated measurements, waveform histograms, and trend plots for visually deciding how a measurement is progressing. These tools allow the user to confirm that their oscilloscope is performing well and that it is meeting the project’s design goals. Automated measurement readouts allow the user to look at waveform characteristics as statistics, so they can repeat them later on.

Since the Tektronix MDO3014 has such a fast waveform capture rate, this model gives the user a similar display to an analog oscilloscope, but instead has more detail, along with the added advantages of digital oscilloscopes. Many video engineers prefer analog oscilloscopes, but the MDO3014 is perfect for video applications because of the following features: IRE and mV graticules, video polarity, HDTV and custom video triggers, holdoff by fields, and an Autoset which can spot video signals. A video picture mode is also available to let the user see the picture of the video signal they are watching.

MDO3014Technical Specifications & Electrical Characteristics Datasheet
Analog channels4
Analog channel bandwidth100 MHz
Rise time (typical, calculated)4 ns
(10 mV/div setting with 50 Ω input termination) 
Sample rate (1 ch)2.5 GS/s
Sample rate (2 ch)2.5 GS/s
Sample rate (4 ch)2.5 GS/s
Record length (1 ch)10 M
Record length (2 ch)10 M
Record length (4 ch)10 M
Digital channels with MDO3MSO option16
Arbitrary Function Generator outputs with MDO3AFG option1
Spectrum analyzer channels1
Standard spectrum analyzer frequency range9 kHz - 100 MHz
Optional spectrum analyzer frequency range with MDO3SA option9 kHz - 3 GHz
High-level descriptionIntegrated Oscilloscope with Six Instruments in One
Commonly used forDesign and Debug, EMI Troubleshooting, Education
Analog Bandwidth100 MHz, 200 MHz, 350 MHz, 500 MHz, 1 GHz
Maximum Analog Sample Rate5 GS/s
Analog Channels2, 4
Record Length10 M
Digital Channels(Optional) 16
Spectrum Analyzer Channel(Standard) 9 kHz - Analog BW (Optional) 9 kHz - 3 GHz
AFGUp to 50 MHz with 13 functions and arbitrary waveform generation
Serial Bus AnalysisTrigger & Decode: I 2 C, SPI, RS-232/422/485/UART, CAN, CAN FD, LIN, FlexRay, USB2.0, MIL-STD-1553, Audio
Advanced AnalysisPower, Limit/Mask, Video
Standard Probing200 MHz, 3.9 pF 500 MHz, 3.9 pF or 1 GHz, 3.9 pF

MDO3014 MDO3000 Series Tektronix Oscilloscope Modules & Options

  • MDO3BND Application module  for the MDO3014 that enables all of the functionality of the MDO3AERO, MDO3AUDIO, MDO3AUTO, MDO3COMP, MDO3EMBD, MDO3FLEX, MDO3LMT, MDO3PWR and MDO3USB Tektronix application modules in a single module. Save money when multiple serial bus debug and analysis application modules are required and easily move the entire set of functionality from one instrument to another. Find out more by viewing the MDO3014 manual.
  • MDO3AERO Aerospace Serial Triggering and Analysis Module - Enables triggering on packet-level information on Tektronix MIL-STD- 1553 buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time- stamp information. MDO3014 Oscilloscope Signal Inputs – Any Ch1 – Ch4, Math, Ref1 – Ref4 Recommended Probing – Differential or single ended (only one single-ended signal required). Additional information is located in the MDO3014 user manual.
  • MDO3AUDIO Audio Serial Triggering and Analysis Module - MDO3014 Tektronix Oscilloscope Enables triggering on packet-level information on I2S, LJ, RJ, and TDM audio buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Tektronix Oscilloscope MDO 3014  Signal Inputs – Any Ch1 – Ch4, any D0 – D15 Recommended Probing – Single ended. Find out more by viewing the MDO3014 datasheet.
  • MDO3AUTO Automotive Serial Triggering and Analysis Module - Enables triggering on packet-level information on CAN and LIN buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time- stamp information. Tektronix Oscilloscopes Signal Inputs – CAN or LIN: Any Ch1 – Ch4, any D0 – D15 Recommended Probing – CAN: Single ended or differential; LIN: Single ended MDO3014. Find out more by viewing the user manual.
  • MDO3COMP Computer Serial Triggering and Analysis Module - Enables Tektronix MDO3014 Oscilloscope triggering on packet-level information on RS-232/422/485/UART buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs – Any Ch1 – Ch4, any D0 – D15 Recommended Probing – RS-232/UART: Single ended; RS-422/485: Differential. Find out more by viewing the MDO3014 user manual.
  • MDO3EMBD Embedded Serial Triggering and Analysis Module - MDO3014  Enables triggering on packet-level information on I2C and SPI buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time- stamp information. Signal Inputs – I2C or SPI: Any Ch1 – Ch4, any D0 – D15 Recommended Probing – Single ended. Additional information is located in the datasheet.
  • MDO3FLEX FlexRay Serial Triggering and Analysis Module - Enables triggering on packet-level information on FlexRay buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, packet decode tables with time-stamp information. Signal Inputs – Any Ch1 – Ch4 (and any D0 – D15 when MDO3MSO option is installed; single-ended probing only) Recommended Probing – Single ended or differential - Find out more by viewing the Tektronix MDO3014 Oscilloscope datasheets and user manual.
  • MDO3USB USB Serial Triggering and Analysis Module - Tektronix MDO3014 Oscilloscope Enables triggering on packet-level content for low-speed, and full-speed USB serial buses. Also enables analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information for low-speed, full-speed, and high-speed USB serial buses. Signal Inputs – Low-speed and Full-speed: Any Ch1 – Ch4, any D0 – D15; Low-speed, Full-speed, and High- speed: Any Ch1 – Ch4, Math, Ref1 – Ref4 Note: High-speed decode support only available on 1 GHz models. Recommended Probing – Low-speed and Full-speed: Single ended or differential; High-speed: Differential. Read more about MDO3000 Series Tektronix Oscilloscopes in the Manual & Datasheets linked on ApexWaves.com
  • MDO3PWR Power Analysis Application Module - Tektronix MDO3014 Oscilloscope Enables quick and accurate analysis of power quality, switching loss,harmonics, safe operating area (SOA), modulation, ripple, and slew rate (dI/dt, dV/dt). More information can be found in the MDO3000 Series Manual.
  • MDO3LMT Limit and Mask Testing Application Module - Tektronix MDO3014 Oscilloscope Enables testing against limit templates generated from “golden” waveforms and mask testing using custom masks. Further reading on MDO3000 Series Oscilloscopes in the datasheet.
  • MDO3AFG - Tektronix MDO3014 Oscilloscope Add arbitrary function generator to any MDO3000 Series product. One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is used to enable the feature and then is not required for future use. Read more in the user manual.
  • MDO3MSO - MDO3014  Add 16 digital channels; includes P6316 digital probe and accessories. One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is used to enable the feature and then is not required for future use. Discover more application modules & option information in the user manual datasheet.
  • MDO3SA - Tektronix MDO3014 Oscilloscope Increase spectrum analyzer input frequency range to 9 kHz – 3 GHz and capture bandwidth to 3 GHz. One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is used to enable the feature and then is not required for future use.Discover more application modules & option information in the user manual datasheet.
  • MDO3SEC - Tektronix MDO3014 Oscilloscope Add enhanced instrument security to enable password protected control of turning on/off all instrument ports and instrument firmware update functionality. One-time, permanent upgrade to any model enabled through software option key. Software option key products require that the instrument model and serial number be provided at the time of purchase. The software option key is specific to the model and serial number combination. MDO3014 Tektronix user manual has additional info.Discover more application modules & option information in the user manual datasheet.
  •         MDO3AFG - Tektronix MDO3014 Oscilloscope Add arbitrary function generator to any MDO3000 Series product. One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is used to enable the feature and then is not required for future use.Discover more application modules & option information in the user manual datasheet.
  •          MDO3MSO - MDO3014  Add 16 digital channels; includes P6316 digital probe and accessories. One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is used to enable the feature and then is not required for future use.Discover more application modules & option information in the user manual datasheet.
  •          MDO3SA - MDO3014  Increase spectrum analyzer input frequency range to 9 kHz – 3 GHz and capture bandwidth to 3 GHz. One-time, permanent upgrade to any model enabled through single-use application module hardware key. The hardware key is used to enable the feature and then is not required for future use.Discover more application modules & option information in the user manual datasheet.
  •          MDO3SEC - MDO3014 Add enhanced instrument security to enable password protected control of turning on/off all instrument ports and instrument firmware update functionality. One-time, permanent upgrade to any model enabled through software option key. Software option key products require that the instrument model and serial number be provided at the time of purchase. The software option key is specific to the model and serial number combination. Learn more about the MDO3014 scope in the datasheet and user manual.

Tektronix MDO3014 Mixed Domain Oscilloscope- FAQ:

Question:

What are the maximum power draw ratings for the MDO3014 TEKVPI probes?

Answer:

There is a max power draw of 25 Watts for the MDO3014.

 

Question:

Will the DVM work on the MDO3014 oscilloscope with a probe?

Answer:

Yes, the DVM works through the analog inputs, so a probe can be used.

 

Question:

Can MSO3000/DPO3000 scopes be upgraded to an MDO3000?

Answer:

No, it is not possible to go from an existing MSO/DPO3000 to a new MDO3000.

 

Question:

If I upgrade my MDO3014 bandwidth, do I receive probes with a higher bandwidth?

Answer:

Probes with a higher bandwidth will only be given if the bandwidth of the upgraded scope exceeds the bandwidth of the original supplied probes.

 

Question:

What is the cooling clearance necessary for the MDO3014?

Answer:

The necessary cooling clearance is 2 inches on the back and left side of the oscilloscope.

MDO3014

Main Image
Tektronix MDO3014 Mixed Domain Oscilloscope | Apex Waves | Image

Secondary Image
Tektronix MDO3014 Mixed Domain Oscilloscope | Apex Waves - Wiring Diagram Image

Mixed Domain Oscilloscope

Call

Call now for best pricing
919 809 5227
Rate the MDO3014

Rated 0/5 based on 0 ratings.
Manufacturer:Tektronix
Model Number:MDO3014
Product Type:Mixed Domain Oscilloscope